Extended ECC modification problem

Publication Date:  2012-07-25 Views:  56 Downloads:  0
Issue Description
When we change mode of Extended ECC from specified to Auto mode the error message appeared (the extended ECC mode conflicted, error code 39122)
Alarm Information
Null
Handling Process
To over come this problem we must clear server and client first then change mode of Extended ECC from specified to Auto mode 
Root Cause
This problem appeared because when the Extended ECC mode was specified we already assigned port number to server and IP address and Port number to Client so we can't change the mode of Extended ECC from specified to Auto mode  
Suggestions
This issue not only appeared with OSN 3500 but also all NG SDH