SXCSA boards are displayed as EXCSA in T2000 due to software features

Publication Date:  2012-07-25 Views:  33 Downloads:  0
Issue Description
During trail creation the following message was reported "Activating path failed, Error Code:82152" and "Low-order cross-connect board doesn't have sufficient high-order path to be assigned to low-order service, Error Code:38882". That means that all VC4 low-order buses are used up. In fact only 32 VC4 low-order buses are used but SXCSA board have 128 low-order buses. But in T2000 SCXSA is displayed as EXCSA.
Alarm Information
"Activating path failed, Error Code:82152"
"Low-order cross-connect board doesn't have sufficient high-order path to be assigned to low-order service, Error Code:38882"
Handling Process
If there is no configuration on the NE just reset the SXCSA board after GSCC is online. If there is traffic on the element the handling order is following:
- Hard reset of standby XCS
- Delete logical standby XCS board from T2000
- Configuration standby XCS as SXCSA board after it’s online
- Waiting for batching backup between standby and active XCS
- Switch working XCS to standby XCS
- Hard reset of active XCS
- Delete logical active XCS board from T2000
- Configuration active XCS as SXCSA board after it’s online
- Waiting for batching backup between active  and standby XCS
Root Cause
SXCSA board can emulate previous versions of the board like EXCSA and UXCSA. After the first power on of a multiplexer SXCSA board go online faster than GSCC. So they can be displayed as EXCSA or UXCSA.
Suggestions
After the first power on check if SXCSA board is working and displayed as SXCSA in T2000.. If not just reset the board after GSCC is online. Problem will be solved.