Active alarm in a CX600. The card flash is full.

Publication Date:  2012-07-27 Views:  88 Downloads:  0
Issue Description
An alarm appears active in one CX600. Version V200R002C02B356:
<CX600>display alarm all 
----------------------------------------------------------------------------
Index    Level        Date        Time                  Info      
1    Warning   09-01-30 22:19:33    The CFcard2 storage media of
                                                              MPU10(Entity) exceeded the prealarm
                                                               threshold 
----------------------------------------------------------------------------
Alarm Information
----------------------------------------------------------------------------
Index    Level        Date        Time                  Info      
1    Warning   09-01-30 22:19:33    The CFcard2 storage media of
                                                              MPU10(Entity) exceeded the prealarm
                                                               threshold 
----------------------------------------------------------------------------
Handling Process
After the alarm appears, we shall delete unnecessary files in the Card Flash.
Root Cause
The devices CX600 keep a record of the logbuffer in the CF.
By command we can change in which CF this files are stored. 
When the CF is full, an alarm appears in the device.
The solution is to delete unnecessary files and the alarm was recovered.
Suggestions
Null 