FAQ-How to Number Back-to-Back Board Slots for NE5000E

Publication Date:  2012-07-27 Views:  108 Downloads:  0
Issue Description
Q:
How back-to-back board slots for NE5000E can be numbered? 
 
Alarm Information
Null
Handling Process
 A:
The convention rules for numbering the master/slave shelf slots uniformly under NE5000E back-to-back products are as follows:
Slots 1 to 16 are the service board slots of the master shelf
Slots 17 to 32 are the service board slots of the slave shelf
Slots 33 and 34 are the main control board slots of the master shelf
Slots 35 and 36 are the main control board slots of the slave shelf
Slots 38 to 41 are the network board slots of the master shelf
Slots 42 to 45 are the network board slots of the slave shelf 
 