How to enable MA5680T ETHB Port to connect to other vendor's equipment

Publication Date:  2012-07-25 Views:  48 Downloads:  0
Issue Description
1.MA5680T ETHB Port can't get up when it is connected to packet generator tool 2.Check the patchcord, the result is OK. 
3.Try loopback ETHB Port, the result is OK.
4. in this case, ETHB is in the slot 0/17.
OLT (ETHB Port 1) --> Packet generator tool (GE port)--> OLT (GICF Port 1)
Alarm Information
Null
Handling Process
In this case, ETHB is in the slot 0/17.
Using command,
get into interface ETHB
#undo isolate board 0/17
Root Cause
The Board is in the isolate state
Suggestions
Null

END