NE_NOT_LOGIN due to ECC features of Metro 1000

Publication Date:  2012-07-25 Views:  57 Downloads:  0
Issue Description
There is a PP-ring consist of three elements NE1-NE2-NE3. NE1 is Metro3000, NE2 is Metro 1000 and NE3 is Metro 500. NE1 is GNE. When the fiber between NE1 and NE3 was cut, NE2 and NE3 log off from T2000. Although it should have taken ECC from another direction from NE1.
Alarm Information
NE_NOT_LOGIN
Handling Process
After fiber was recovered we set ECC parameters correctly. 3-OI2D-2 port is connected with Virtual_NE so in DCC Management we disabled 3-OI2D-1 port. Other port set as enabled
Root Cause
After fiber was recovered we checked DCC Management on every NE. On NE2 (Metro 1000) 3-OI2D-2 port was connected to the Virtual_NE and in DCC Management 3-OI2D-2 was disabled. But all Metro 1000 (V2 and V3 version) have the same feature with ECC channels on OI2D boards. If you want to disable physical OI2D-1 port than in DCC Management you should disable OI2D-2 port and if you want to disable physical OI2D-2 port than in DCC Management you should disable OI2D-1 port. So in our case when in DCC Management 3-OI2D-2 port was disabled in fact physical 3-OI2D-1 port was disabled. And this port is connected with NE1 (Metro 3000). So for NE2 both directions for ECC channel were unreachable - one direction was physically disconnected due to fiber cut, and another direction was disabled manually. 
Suggestions
Be aware that all Metro 1000 (V2 and V3 version) have the same feature with ECC channels on OI2D boards. If you want to disable physical OI2D-1 port than in DCC Management you should disable OI2D-2 port and if you want to disable physical OI2D-2 port than in DCC Management you should disable OI2D-1 port.