FAQ-OSN1500 AUX board Power_abnormal alarm parameter description

Publication Date:  2012-07-25 Views:  45 Downloads:  0
Issue Description
Q, OSN1500 AUX board Power_abnormal alarm parameter description
Alarm Information
Null
Handling Process
A, para0 fixed value 0x01; para1 fixed value 0x00; para2 fixed value 0x01; para3(transform into binary,bit=1 is available): bit0 // pick the board 1.5 V voltage value abnormal bit1 // pick the board 1.8V voltage value abnormal bit2 // pick the board voltage module 3.3 V voltage stage abnormal; bit3 // pick the board backup voltage module 3.3 V voltage stage abnormal
Root Cause
Null
Suggestions
recently, every version of OSN1500 equipment AUX board Power_abnormal alarm parameter definitions are all the same.