Problems for associate the VC12 to the VCTRUNK in SSN1EFS4 Board

Publication Date:  2012-07-25 Views:  85 Downloads:  2
Issue Description
Huawei engineer was trying to create an Ethernet service to N1EFS4 Board in slot 11 from OSN 1500 with 5.21.17.31p01 in VC4-4 at VC12 level in one of the available VCTRUNK (1-12), and when we are trying to associate the service to the bound path appears the attached error. error.jpg
Alarm Information
Null
Handling Process
Huawei engineer send the following command for querying the services and for configure the services again:
  
:ethn-cfg-get-vctrunkpath:bid,allport;
:ethn-cfg-get-vctrunkreal:bid,allport;
 
:ethn-cfg-add-vctrunkpath:11,vctrunk11,up,vc12,1,45
:ethn-cfg-add-vctrunkpath:11,vctrunk11,down,vc12,1,45
:ethn-cfg-get-vctrunkpath:bid,allport;
:ethn-cfg-get-vctrunkreal:bid,allport;
After this command line was done, Huawei engineer went to T2000 and send an upload and realize that the services were already associated to the bound path, and then, the services were associated using t2000 without any problem to the board.
Root Cause
Is possible that the configuration in T2000 was not the same that the equipment so, Huawei engineer send an upload and try to do the configuration again, however, the problem was again as the attachment error.jpg
Huawei engineer tried to do the configuration using navigator, because maybe the board was blocked and doing a query of the services and trying to configure the services again the problem could be solved.
Suggestions