No Resync Ratio statistic as incorrect port configuration

Publication Date:  2012-07-25 Views:  114 Downloads:  0
Issue Description
IManager N2510 V200R001C03B029. Bookmark “Network Analysis”, daily Resync Ratio statistic  (screen shot  “Resync Ratio.JPG”). There is statistic on “Total Valid Ports” but there is no one Resync. Other statistic is ok (for example “Bit Error Ratio.JPG”),  other function of N2510 ok.
      
Alarm Information
Null
      
Handling Process
It’s need not to specify rack in port description. For example description 10.10.10.10/0/0/0 � correct and 10.10.10.10/1/0/0/0 � incorrect. Example of correct excel port description file in attachment (ports.xls).
Delete rack information in port description � problem solved.
      
Root Cause
SNMP configuration ok 
      
Suggestions
Null
      

END