No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Remote monitoring for newly installed NE cannot be performed because of Incorrect DCC configuration

Publication Date:  2012-07-25 Views:  40 Downloads:  0
Issue Description
Customer have 1 new node interconnect with existing network.
No problem when perform local console for both NEs but do monitoring for remote node.
Alarm Information
Null
Handling Process
Compare DCC configuration for both sites, found 1 site configure as "HWECC" and the other site configure as "IP".
Change the "IP" configuration to "HWECC", remote console success. 
Root Cause
Checked fiber connection, service is ok when tested with Testgear.
Check ECC by Issue "cm-get-eccroute", can't found remote NE.
DCC (D1-D3) enabled and obtained.
Suggestions
Always have to make sure DCC configuration for interconnect NEs is consistent.

END