No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Setting of Clock Pin Assignment RJ45 of Metro 1000

Publication Date:  2012-07-25 Views:  44 Downloads:  0
Issue Description
Customer inquiry regarding PIN assignment of SYN RJ45 port for connection to other connector at other end.
Alarm Information
Null.
Handling Process
Pin assignments of the SYNC 1/2 external clock interface .
Pin No Definition Function
1 EXT1R+ Input port for the first external clock
2 EXT1R�
-------------------------------------------------------------------------------
4 EXT1T+ Output port for the first external clock
5 EXT1T�
-------------------------------------------------------------------------------
3 EXT2R+ Input port for the second external clock
6 EXT2R�
-------------------------------------------------------------------------------------
7 EXT2T+ Output port for the second external clock
8 EXT2T�
Physical Interconnection to other devices.
PIN  Def          Color                      Destination
1    EXT1R+   White/Green------>Input port for the first external clock
2    EXT1R�   Green-------------->Input port for the first external clock
3    EXT2R+   White/Orange---->Input port for the second external clock
4    EXT1T+    Blue---------------->Output port for the first external clock
5    EXT1T�    White/Blue------->Output port for the first external clock
6    EXT2R�   Orange------------>Input port for the second external clock
7    EXT2T+   White/Brown----->Output port for the second external clock
8    EXT2T�    Brown------------->Output port for the second external clock

Colors coding are depend on customer and operators. Some use a different coding for their standard, but pinning from Metro 1000 RJ45 SNYC 1/2 
must exactly as defined.
Root Cause
1. The SCB board of the OptiX 155/622H combines the functions of the line, tributary, cross-connect, clock, SCC, and orderwire modules. Clock unit represent by RJ45 port (SYNC 1/2).
2. SYNC 1/2 Indicates a two-input/output external clock interface. The impedance of the interface is 120 ohms. The interface can be used to transparently transmit DCC bytes.
3. An external clock cable is used to input/output external clock signals.
The impedance of the external clock cable is 120 ohms. The external clock cable uses an RJ-45 connector at one end to connect to the external clock input/output interface of the SCB, and uses another connector (the type of connector 
depends on the situations of the site) to connect to the external equipment.
4. In this situation, physical wire attachment must be exactly correct if the intermidiate device needed, such as patching block, then connecting to 
BALUN, then signal running by coax cable to external clock equipment or etc.
Suggestions
 Please know about it.

END