Metro Ethernet CX600: Voltage sensor exceed lower major limit

Publication Date:  2012-07-27 Views:  39 Downloads:  0
Issue Description
----------------------------------------------------------------------------
Index    Level        Date        Time                  Info      
1        Error        09-08-03    14:18:45    The address0,channel5  voltage 
                                              sensor of SlotID 9(entity) excee
                                              d lower major limit 
----------------------------------------------------------------------------   
PCB   I2C Addr Chl Status Required LowAlmThreshold HighAlmThreshold Vol Ratio
                                   Major   Fatal   Major   Fatal   
-------------------------------------------------------------------------------
SRUA  1   0    0   NORMAL  5.00    4.55    4.05    5.57    6.07    5.10  0.38  
SRUA  1   0    1   NORMAL  3.30    3.00    2.67    3.67    4.00    3.48  0.58  
SRUA  1   0    2   NORMAL  2.50    2.25    2.00    2.75    3.00    2.55  0.76  
SRUA  1   0    3   NORMAL  1.80    1.62    1.44    1.98    2.16    1.81  1.00  
SRUA  1   0    4   NORMAL  1.20    1.08    0.96    1.32    1.44    1.21  1.00  
SRUA  1   0    5   MAJOR   1.14    1.03    0.91    1.25    1.37    0.99  1.00   <<<
SRUA  1   0    6   NORMAL  5.00    4.55    4.05    5.57    6.07    5.07  0.38
Alarm Information
The address0,channel5 voltage sensor of SlotID 9(entity) exceed lower major limit.
Handling Process
This problem will be solved in future versions (the thresholds values will be reviewed), but there is a command to change the values of the thresholds manually, just to clear the alarm if the SW upgrade is not planned by the customer.
1.- Enter in sys and hidecommand:
<Quidway>sys
Enter system view, return user view with Ctrl+Z.
[Quidway]_h
Now you enter a hidden command view for developer's testing, some commands may 
affect operation by wrong use, please carefully use it with HUAWEI engineer's 
direction.
[Quidway-hidecmd]
2.- Type the following command (this example, for address 0 channel 5):
[Quidway-hidecmd]voltage-threshold slot 9 i2cid 1 address 0 channel 5 low-major 90 low-fatal 80 high-major 110 high-fatal 120  
Voltage threshold changed success!
3.- We can review the alarm list and the new thresholds:
<Quidway>displ alar all
----------------------------------------------------------------------------
 NO alarm 
----------------------------------------------------------------------------   
<Quidway>displ volt slo 9
PCB   I2C Addr Chl Status Required LowAlmThreshold HighAlmThreshold Vol Ratio
                                   Major   Fatal   Major   Fatal   
-------------------------------------------------------------------------------
SRUA  1   0    0   NORMAL  5.00    4.55    4.05    5.57    6.07    5.10  0.38  
SRUA  1   0    1   NORMAL  3.30    3.00    2.67    3.67    4.00    3.48  0.58  
SRUA  1   0    2   NORMAL  2.50    2.25    2.00    2.75    3.00    2.55  0.76  
SRUA  1   0    3   NORMAL  1.80    1.62    1.44    1.98    2.16    1.81  1.00  
SRUA  1   0    4   NORMAL  1.20    1.08    0.96    1.32    1.44    1.20  1.00  
SRUA  1   0    5   NORMAL  1.14    0.90    0.80    1.10    1.20    0.99  1.00  <<<
SRUA  1   0    6   NORMAL  5.00    4.55    4.05    5.57    6.07    5.05  0.38
Root Cause
SW Version: V300R006C01B133 or V300R006C01B135.
Many MPUs (or SRUs if CX600-8) use the new CPU with the 1.0V core voltage, some versions are not compatible with the new CPU voltage and displays the alarm. If this alarm is major or critical depends on the threshold configured by default.
Suggestions
Null

END