Problem With Activation ASON

Publication Date:  2012-07-25 Views:  42 Downloads:  0
Issue Description
Huawei engineer activated the ASON feature over an OSN 3500 (ver 5.21.17.31P01) by using OptiX Navigator tool. However, when trying to check the ASON 
parameters using iManager T2000 V2R6C01, those parameters were not shown in the NMS, appearing a error message "Error code:122341" (Refer to 
attachment Error ASON.jpg)
Alarm Information
Null
Handling Process
1. Through T2000, using the Configuration Data Management menu, perform an Upload over the NE.                                           
2.After finishing upload proccess,check the ASON parameters (LMP) in T2000.
Root Cause
The ASON parameter were not uploaded correctly in the NM system.
Suggestions
When performing changes in ASON parameters over any NE, please be aware of the final configuration of such parameters. It is advisable to perform an
 upload over the NE, to update current configuration in the NMS.