FAQ-Can the FE-Type Daughter Board of the MCUA Control Board of the MA5606T Be Directly Replaced with the GE-Type Daughter Board

Publication Date:  2012-07-25 Views:  64 Downloads:  0
Issue Description
Q:
The MCUA control board of MA5606T has only one slot for a daughter board. If the original daughter board of MCUA is O2FN, can O2FN be directly replaced with the O2GN daughter board, without any change to data configuration?
Alarm Information
Null
Handling Process
A:
Yes, the FE-type daughter board (such as O2FN) can be directly replaced with the GE-type daughter board (such as O2GN), without any change to data configuration. This means that you neither clear the database nor delete data configuration related to the upstream port of the MA5606T to replace the daughter board of the MCUA control board.
Root Cause
Null
Suggestions
O2FN can be directly replaced with O2GN, without any change to data configuration.