FAQ-What Are the Commands for Querying the OLT Version

Publication Date:  2012-07-25 Views:  73 Downloads:  0
Issue Description
Q:
What are the commands for querying the OLT version?
Alarm Information
Null
Handling Process
A:
1. If running the display language command, you can query only the version that is running in the system, namely, the version of the active control board.
ma5680t(config)#display language                                         
  Local: 
      Description: CHINESE SIMPLIFIED (DEFAULT LANGUAGE) 
      Version:     MA5600V800R105C33B050  
  General:  
      Description: ENGLISH (DEFAULT LANGUAGE) 
      Version:     MA5600V800R105C33B050                 
ma5680t(config)# 
2. If running the display version command, you can query only the R-level version and the board hardware version of the control boards.
ma5680t(config)#display version 0/9    
  Main Board: H801SCUL    
  ---------------------------------------                                       
  PCB           Version: H801SCUL  VER C                                        
  Base     BIOS Version: 200                                                    
  Extended BIOS Version: 204                                                    
  Software      Version: MA5600V800R105                                         
  Logic         Version: (U27)102(U15)102(U16)104(U100)108   
  MAB           Version: 0004                                                   
ma5680t(config)#display version 0/10                                       
  Main Board: H801SCUL    
  ---------------------------------------                                       
  PCB           Version: H801SCUL  VER C                                        
  Base     BIOS Version: 200                                                    
  Extended BIOS Version: 204                                                    
  Software      Version: MA5600V800R105                                         
  Logic         Version: (U27)102(U15)102(U16)104(U100)108    
  MAB           Version: 0004     
ma5680t(config)# 
3. If running the display compiling time active command or the display compiling time standby command, you can query the program file version saved in the flash memory of the active or the standby control board respectively.
ma5680t(su)%%display compiling time active   
  Copyright(C) Huawei Technologies Co., Ltd. 2002-2008. All rights reserved.   
  Version        : MA5600V800R105C33B050        
  Compiled time  : 2008-09-23  02:22:06  
  Local language   : CHINESE SIMPLIFIED (DEFAULT LANGUAGE)   
  Compiled time    : 2008-09-23  02:44:30            
  General language : ENGLISH (DEFAULT LANGUAGE)   
  Compiled time    : 2008-09-23  02:44:36      
  Current Data Area: Area B           
  ------------------------------------------------------------                  
  [Area A]    
  Data version  :  MA5600V800R105C33B050   
  [Area B]                                                                      
  Data version  :  MA5600V800R105C33B050   
ma5680t(su)%%display compiling time standby   
ma5680t(su)%%   
  Copyright(C) Huawei Technologies Co., Ltd. 2002-2008. All rights reserved. 
  Version        : MA5600V800R105C33B019         
  Compiled time  : 2008-06-19  02:46:54  
  Local language   : CHINESE SIMPLIFIED (DEFAULT LANGUAGE)   
  Compiled time    : 2008-06-19  17:08:02   
  General language : ENGLISH (DEFAULT LANGUAGE)  
  Compiled time    : 2008-06-19  17:08:09    
  Current Data Area: Area B    
  ------------------------------------------------------------                  
  [Area A]    
  Data version  :  MA5600V800R105C33B019    
  [Area B]     
  Data version  :  MA5600V800R105C33B019    
ma5680t(su)%% 
Root Cause
Null
Suggestions
If the versions of the active and the standby control boards are different, it is unable to synchronize the database or to implement the active/standby switchover.

END