FAQ-Precautions for Configuring the MG Interface Data When the MA5616 Is Interconnected with the Z Softswitch

Publication Date:  2012-07-25 Views:  72 Downloads:  0
Issue Description
Q:
What are the precautions for configuring the MG interface data when the MA5616 V800R306C01B053 is interconnected with the Z softswitch?
Alarm Information
Null
Handling Process
A:
1. Change the digitmap matching mode to longest match, corresponding to the value 1:Longest Match. The default value is 0:Shortest Match.
MA5616(config-if-h248-1456)#mg-software parameter 13 ?
---------------------------------------------
  Command of h248mgid-1456 Mode:
---------------------------------------------
{value<L>}
                      DMM match mode
                      0: Protocol define
                      1: Longest
                      2: Shortest                          
2. According to actual condition, modify the maximum number of RTP terminations, which cannot be greater than the maximum number of RTP terminations configured on the Z softswitch. By default, the maximum number of RTP terminations is 64, and it can be modified according to the actual number of ports.
MA5616(config-if-h248-1456)#mg-software parameter 24 ?
---------------------------------------------
  Command of h248mgid-1456 Mode:
---------------------------------------------
{value<L>}
                      The Max number of RTP terminal TID <0,64>
                                                                             
3. Set the profile index to 6:ZTE_AGW/1("ZTE_AGW/1"), and reset the H.248 interface to make the setting take effect. By default, the profile index is 1:NoProfile("").
MA5616(config-if-h248-1456)#if-h248 attribute profile-index ?
---------------------------------------------
  Command of h248mgid-1456 Mode:
---------------------------------------------
index<E>
                      0:CustomizingProfileTemplet("")
                      1:NoProfile("")
                      2:BT_AGW/3("BT_AGW/3")
                      3:FT_AGW/2("FT_AGW/2")
                      4:KPN_AGW/1("KPN_AGW/1")
                      5:PCCW_AGW/1("PCCW_AGW/1")
                      6:ZTE_AGW/1("ZTE_AGW/1")
Root Cause
Null
Suggestions
Null

END