NE ID cannot re-create after old ID is deleted.

Publication Date:  2012-07-25 Views:  43 Downloads:  0
Issue Description
Prior this case happened, SCC had faulty. Then replaced SCC board, however version of the board is difference. It V1R3 but NE version is V1R1. Then we replaced
 a new board in NE and create temporary ID before delete the target NE which ID 5.
After successfully create a new ID, then we delete the ID 5. To change ID to 5 but got message show ID conflict.  Mean that ID still exist on system database.
Alarm Information
No alarm information.
Handling Process
1. At the same time, UNIX server got problem because of router connection problem which required to the restart back the Unix server.
2. After restart server, we try to check back and found NE ID 5 not in system anymore.
Check by :cm-get-eccroute, found no more NE ID 5. Then change the NE ID and succeed.
3. Suspected maybe the version unmatched could cause the 
abnormal operation like this. Already advise by HQ to upgrade the version to V1R3 because current used version is V1R1 which is very old version and maybe
 got bug defect. However, due to commercial issue, SCC is replace first to make the NE can monitor and in the same time  customer want to keep the NE ID 
same as previous.
Root Cause
Analysis:
1. Site NE-5 TRA cannot monitor by NMS because SCC problem. Then we replaced the SCC with a new one and now NE-5TRA can monitor by NMS again. 
2. In troubleshooting process found difficulties that the new SCC cannot be change the NE-ID become ID 5 because conflict ID. Please see the result below by Navigator.
#9-1:szhw [][][2009-08-15 02:16:23]>
:cm-set-neid:0x90005
failed! cmd:0x9101 error:0x9888 NSERR_CM_NEID_CONFLICT??????
3. Change to other NE ID to ID 170 then it's ok. Then create a new NE OSN 3500 in T2000 topology and copy all data from original NE-5 TRA then download configuration from NM to NE. After that NE ID 170 can be monitored by NMS and all configurations has been successfully downloaded, 
then delete the original NE-5 TRA. After that try again to modify NE-ID to ID 5 by NMS T2000 but it still cannot be done.  
4. Then check the ECC route by Navigator to check destination ID still exist or not.
 #9-170:szhw [][][2009-08-15 03:14:57]>
:cm-get-eccroute
ECC-ROUTE?????????????????????????????????????????????? 
DST-ID??   DXC-ID     DISTANCE?   LEVEL? MODE?    SCC-NO? PEER-SCCNO?????????????? 
0x00090004? 0x00090004? 0???????? 4????? auto????????? 0?????? 2??????????????????????? 
0x00090005? 0x00090004? 3???????? 4????? auto????????? 0?????? 2??????????????????????? 
0x00090006? 0x00090004? 3???????? 4????? auto????????? 0?????? 2??????????????????????? 0x00090007? 0x00090004? 1???????? 4????? 
auto????????? 0?????? 2??????????????????????? 
0x00090008? 0x00090004? 2???????? 4????? auto????????? 0?????? 2??????????????????????? 
0x00090009? 0x00090004? 3???????? 4????? auto????????? 0?????? 2??????????????????????? 
0x0009000c? 0x00090004? 4???????? 4????? auto????????? 0?????? 2??????????????????????? 
0x0009000d? 0x00090004? 3???????? 4????? auto????????? 0?????? 2??
Found the ID 5 still exist., that why it appear ID conflict.
Suggestions
Conclusion:
1. Normally NE ID can re-create after old one is deleted.
2. Version SCC difference with NE version might be the reason, before this HQ already advise that abnormal operation might happen if version is not upgrade 
or downgrade.
Suggestion:
1. Old NE version should upgrade to the newer version to avoid bug and abnormal operation.
2. Some old version already discontinuance support by HQ and some spare parts not produce anymore.
3. Version match should be check carefully in version match table.

END