No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Pre-configuration Cannot Be Performed After the N2000 BMS Is Updated to Version V200R012C03

Publication Date:  2012-07-25 Views:  21 Downloads:  0
Issue Description
When you pre-configure the N2000 BMS V200R012C03, the PON-related profiles cannot be added, In sysmonitor, start the PON service management process. This process, however, cannot be started, and a message is displayed, indicating that there is no license authorization. In this case, pre-configuration cannot be performed.
Alarm Information
The process fails to start because there is no license authorization.
Handling Process
Add the option of MA5680T management function software package to the license, and then import the new license.
Root Cause
The N2000 BMS V200R012C03 has the resource control license and the function control license, and these two licenses are independent from each other. Operations on the PON-related profiles can be performed only when the license includes the option of MA5680T management function software package.
Suggestions

1. In fields Product=BMS, Feature=INSTALL, and Function= of the commercial license, check whether Function= contains the LNS1WGZJ08=1 function. If this function is not configured, pre-configuration cannot be performed.

2. If this function is not configured but pre-configuration needs to be performed, use the temporary license. Then, configure this function in the newly applied license.

END