FAQ-How to modify board temperature thresholds

Publication Date:  2012-07-27 Views:  56 Downloads:  0
Issue Description
CX600 with VRP Version 5.60 (V300R006C01B135)
In the device, we detected Alarm temperature in Slot1
Alarm Information
The alarm is the following:
The address7,channel0  temperature sensor of SlotID 1(entity) exceed upper minor limit.
<Quidway>display temperature slot 1
 Base-Board, Unit:C, Slot1
PCB   I2C Addr Chl  Status  Minor Major Fatal Adj_speed Temp 
                                              TMin Tmax (C)  
-----------------------------------------------------------------
LPUK  1   0    0    NORMAL  70    80    90    65   70   64        
LPUK  1   1    0    NORMAL  76    85    95    65   75   64        
LPUK  1   2    0    NORMAL  73    83    93    63   73   67        
LPUK  1   4    0    NORMAL  70    80    90    60   70   68        
LPUK  1   5    0    NORMAL  70    80    90    60   70   58        
LPUK  1   6    0    NORMAL  70    80    90    60   70   64        
LPUK  1   7    0    MINOR   66    75    80    60   66   65        <<<<
LPUK  2   76   2    NORMAL  90    96    102   80   90   58        
EBGF  3   73   0    NORMAL  75    85    91    60   70   25        
EBGF  3   74   0    NORMAL  80    90    96    65   75   31        
EBGF  4   73   0    NORMAL  75    85    91    60   70   30        
EBGF  4   74   0    NORMAL  80    90    96    65   75   36        
Handling Process
With the permission of the customer, we can modify the temperature thresholds to clear the alarm. We only modify the MINOR threshold, as th alarm is also MINOR. Do as follows:
<Quidway>system
Enter system view, return user view with Ctrl+Z.
[Quidway]_h
Now you enter a hidden command view for developer's testing, some commands may affect operation by wrong use, please carefully use it with HUAWEI engineer's direction.
[Quidway-hidecmd]
[Quidway-hidecmd]temperature-threshold slot 1 i2cid 1 address 7 channel 0 minor 70 major 75 fatal 80 
Temperature threshold changed success!
[Quidway-hidecmd]
Then, we can check the new threshold, and the alarm clears:
<Quidway>display temperature slot 1
 Base-Board, Unit:C, Slot1
PCB   I2C Addr Chl  Status  Minor Major Fatal Adj_speed Temp 
                                              TMin Tmax (C)  
-----------------------------------------------------------------
LPUK  1   0    0    NORMAL  70    80    90    65   70   64        
LPUK  1   1    0    NORMAL  76    85    95    65   75   64        
LPUK  1   2    0    NORMAL  73    83    93    63   73   67        
LPUK  1   4    0    NORMAL  70    80    90    60   70   68        
LPUK  1   5    0    NORMAL  70    80    90    60   70   58        
LPUK  1   6    0    NORMAL  70    80    90    60   70   64        
LPUK  1   7    0    NORMAL  70    75    80    60   66   52     <<<<
LPUK  2   76   2    NORMAL  90    96    102   80   90   58        
EBGF  3   73   0    NORMAL  75    85    91    60   70   25        
EBGF  3   74   0    NORMAL  80    90    96    65   75   31        
EBGF  4   73   0    NORMAL  75    85    91    60   70   30        
EBGF  4   74   0    NORMAL  80    90    96    65   75   36  
Root Cause
When this kind of alarm appears, the following is the procedure to follow:
- Check the air filters.
- Check the fan.
- Check the environmental temperature.
In this case, the temperature in the site was too high, more than 28?C. This problem cannot be solved by Huawei, the site?s owner is the customer. We only can change the temperature thresholds.
Suggestions
This measure has to be made only with the customer permission. Theorically, the main problem is still the hifh temperature of the place. The customer should regulate the environmental temperature and adjust the thresholds again. The high temperature is a risk for the device components.

END