FAQ-How to Upgrade the Standby Control Board of the MA5680T to R62

Publication Date:  2012-07-25 Views:  64 Downloads:  2
Issue Description
Q:
Currently, the OLT is undergoing the upgrade from V800R105 to V800R006C02. Considering security, certain carriers upgrade only one control board even when two control boards are configured, and the other control board is not completely inserted into the slot. The standby control board is used to recover services in case of an upgrade failure. When the active control board is upgraded successfully, check whether services are normal. If yes, the standby control board can be upgraded to V800R006C02. For details about how to upgrade the standby control board, the following solutions are available.
Alarm Information
Null
Handling Process
A: 
Solution 1 (services are interrupted)
1. Preparations before the upgrade
save      //Save the configurations.
display curr     //Query the configurations.
display language    //Query the host version.
display version 0/X   //Query the board version.
display board 0     //Query the board states.
display board 0/x    //Query the service port states.
display vlan all       //Query the VLAN information.
display interface vlanif     //Query the vlanif information.
display interface meth         //Query the management information about control boards. backup data tftp 10.11.104.5 ma5680newdata    //Back up the database file. backup configuration tftp 10.11.104.5 ma5680oldconfile    //Back up the configuration file.
2. Power off the system, remove the active control board, and insert the standby control board. After the standby control board works normally, upgrade it according to the normal upgrade procedure. For details, see the V800R006C02 Upgrade Guide.
2. Upgrade steps: load packetfile tftp 10.11.104.5 sculv8r6c02_mainboardpacket.bin active     //Load the control board program package file.
load data tftp 10.11.104.5 ma5680newdata active   //Load the database file. (the database file backed up in step 1)
load packetfile tftp 10.11.104.5 MA5600V800R006C02_package.bin active      //Load the IO board program package file (the IO board program package file extracted from the previous upgrade)
reboot system    //Reboot the system.
4. Insert the previous active control board, and perform step 5 after the registration of this board and the data synchronization between two control boards. 
5. Verify the upgrade.
display cu     //Query the configurations.
display language    //Query the host version.
display version 0/X   //Query the board version.
display board 0     //Query the board states.
display board 0/x    //Query the service port states.
display vlan all       //Query the VLAN information.
display interface vlanif     //Query the vlanif information.
display interface meth         //Query the management information about control boards.
display io-packetfile information         //Query the IO board program package file. The version should be the same as the description in the Release Notes.
diagnoseautosave interval on       //Enable the autosave function.
B: Solution 2 (services are not interrupted)
1. Preparations before the upgrade
the same as those of solution 1
2. Retain the previous active control board. In this way, services run normally. Insert the control board to be upgraded into another slot and upgrade the board at the BIOS booting stage. 
3. Upgrade steps
1. At the BIOS booting stage, press D to enter the loading state, and delete the previous extended BIOS.
2. Load the extended BIOS of the R62 version.
3. Load the host program package file sculv8r6c02b086_mainboardpacket.bin of the R62 version.
4. Load the blank database of the R62 version. Then, the standby control board will reset automatically. After the reset, the standby control board will automatically synchronize the current database and board package file from the active control board.
For detailed steps, see the attachment.
4. Verify the upgrade.
The same as that of solution 1
Root Cause
Null
Suggestions
Solution 2 is recommended.

END