FAQ-How Does the ETHB Board Implement Inter-board Aggregation in the MA5680T V800R006

Publication Date:  2012-07-25 Views:  53 Downloads:  0
Issue Description
Q: 
How does the ETHB board implement inter-board aggregation in the MA5680T V800R006?
Alarm Information
Null
Handling Process
A:
The MA5680T V800R005 (including V800R105) does not support inter-board aggregation. The MA5680T V800R006 supports inter-board aggregation. The boards to be aggregated, however, must be bound before link-aggregation. To bind two boards, the input slot IDs must be in the [1,2], [3, 4] …, or [17, 18] format. That is, only the two boards in adjacent slots such as [1, 2], [3, 4], … or [17, 18] can be bound. (In the case of the MA5683T, only the two boards in slots [0,1] or [2,3] can be bound.
For example, to bind boards in slots 0/3 and 0/4, do as follows:
huawei(config)#bind board
{ frameid/slotid<S><Length 3-8> }:0/3
{ frameid/slotid<S><Length 3-8> }:0/4
Root Cause
Null
Suggestions
Null

END