FAQ- What Need to Be Noticed When You Configure Protect Groups to PON Ports on the Same EPBC Board or the Same EPBD Board

Publication Date:  2012-07-25 Views:  51 Downloads:  0
Issue Description
Q:
What need to be noticed when you configure protect groups to PON ports on the same EPBC board or the same EPBD board?
Alarm Information
Null
Handling Process
A:
When you configure protect groups to PON ports on the same EPBC board or the same EPBD board, the following hardware requirements must be met: 
In the case of the EPBC board, ports 0 and 1, or ports 2 and 3 cannot be configured as protect groups. That is, ports 0 and 1, and ports 2 and 3 cannot be protect groups; but ports 0 and 2, ports 0 and 3, ports 1 and 2, and ports 1 and 3 can be protect groups. 
In the case of the EPBD board, ports 0 and 1, ports 2 and 3, ports 4 and 5, and ports 6 and 7 cannot be configured as protect groups. That is, the same as EPBC.
Root Cause
Null
Suggestions
Null