No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

FAQ-How to Select the Upstream Clock Source for the STM-1 Interface of an OLT

Publication Date:  2012-07-25 Views:  52 Downloads:  0
Issue Description
Q:
How to select the upstream clock source for the STM-1 interface of an OLT?
Alarm Information
Null
Handling Process
A:
Generally, an OLT selects the line clock of the STM-1 interface as the system clock, and the entire SDH network is with the same clock source. This requires less VC12 adjustment. Versions earlier than V800R006C02SPC103 use the line clock of the STM-1 interface as the system clock, but the service cannot be provisioned. Therefore, the OLT of this version does not select the line clock of the STM-1 interface as the system clock; however, versions later than V800R006C02SPC104 select the line clock of the STM-1 interface as the system clock.
 
Root Cause
Null
Suggestions
Null

END