about limitation of VLAN ID max number for MSTP product

Publication Date:  2012-07-25 Views:  58 Downloads:  0
Issue Description
Engineer try to create EPLAN service with VLAN ID from 3000 to 3999, but get error code 39802, numer of VLANs exceeds the limit.  Has checked the VLAN filter 
table, the number of  VLAN ID in each VB do not reach 4096. The total number of VLAN ID in all the VB is 8192.
Alarm Information
numer of VLANs exceeds the limit, error code 39802, 
Handling Process
optimize the VLAN IDs, make the max number in 8192.
Root Cause
Because the GSCC has the limitation for total VLAN ID max number that it can not over 8192. So if you want to config more VLAN ID when the number already 
get to 8192, it will report error code 39802. That is the hardware limitation, by now no software version can solve this.
Suggestions
Pls optimize the VLAN ID distribution plan, and do not exceed 8192.