TQS has ODU1-PM-SSF alarm and can not be clear

Publication Date:  2012-07-25 Views:  31 Downloads:  3
Issue Description
There are 3 6800 net element, a trail starts on NE61TQS-NS2, and then passes through electrically on NE334 between NS2-NS2 and finally sinks in NE208 of NS2-TQS.
There is a ODU1-PM-SSF alarm on the TQS of NE61,and can not be cleared.
Alarm Information
ODU1-PM-SSF
Handling Process
We find the ODU1-PM-AIS on TQS of NE 61, and there are no such alarms on the other NEs. That means there is something wrong on the NS2 of the NE61. Then we take actions as follow:
1.login the NE61 through Navigator
2.Use command :mon-get-moduleinfo:$BID to find the "ClassID" and "functioned".
  Use command :mon-get-dump: boardid, classID, functioned to find the DUMP information.
  $BID is short for Boardid
  ClassID is something like " IND2BDCFGModule.CND2BDCFGModule"
3.The result is like this
     ODU1 |      |                           V5 UP                        |        V5 Down        |        
  ______| SYS |_____________________________________________|_______________________|        
          |    |         Alm         |         Bip8        |    FIFO   |    Alm    |    Bip8   |        
          |    | CUR HIS CUR HIS    | LOW HIGH LOW HIGH   | CUR HIS | CUR HIS | LOW HIGH |        
  Chal1 |   256    7    7    7    7    | 0    0    0    0    | 4    4   | 6    0    | 0    0    |      
  Chal2 |   256    7    7    7    7    | 0    0    0    0    | 4    4   |  6    0   | 0    0    |      
  Chal3 |   256    7    7    7    7    | 0    0    0    0    | 4    4   |  6    0   | 0    0    |      
  Chal4 |   256    7    7    7    7    | 0    0    0    0    | 4    4   | 6    0    | 0    0    |      
                                                                                                        
          |         30009 UP       |       30009 Down       |                                           
          | cha0 cha1 cha2 ch3 ch4 | cha5 cha6 cha7 ch8 ch9 |                                           
    Alm   | 96 132 132 132 132 | 96 96 96 96 96 |                                                       
  BIP8_PM | 16312 4082 4082 4082 4082 | 16414 4052 4017 4017 4052 |                                     
  BIP8_SM | 16312 0 0 0 0 | 16414 4053 4087 4053 4053
Check the area where the number is marked with red color, If it show "6", then check the blue number which is on the same array with the red ones.
And chal1 means channel 1. Chanl2 means channel 2, and so on.
If the channel of NS2 which connect to the channel with alarm ODU1-PM-SSF on TQS has the number “6”. It means that the port is down, we has to reset it to solve the problem.
Root Cause
ODU1-PM-SSF can not lead us to the business with problem, because it is just a sign for warning. After checking the log on all of these NE, there is no other alarm. The most 
possible reason for this is the “Non-intrusive” was disabled on all these NEs, so we enable it and collected the data again. 
Suggestions
When we see the alarm ODU1-PM-SSF, we should check the other alarm like ODU1-PM-AIS and ODU1-PM-OCi to locate the problem.