No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

40G work with OLP protection

Publication Date:  2012-07-25 Views:  48 Downloads:  3
Issue Description
When 40G line or OTU boards work with OLP protection and when happen OLP switch, 40G boards receive AIS signal, dispersion in the line changes, 40G board 
starts to search dispersion. Switching time can reach tens seconds.
Alarm Information
Comes ODU3_PM_SSF alarm. When start dispersion search appear OTU3_LOF alarm.
Handling Process
To avoid this problem necessary to set dispersion manually. Before necessary to make dispersion search for the main path. Save dispersion value. Then make 
OLP switch to the protection path, make dispersion search. Save dispersion value. Then necessary to set manually dispersion value which is in the middle between
 the first and second value. Set Fine Tune switch to disable (check attachment) Check perfomance before correction. If it is OK, then no problem. If FEC before 
correction is too high, then necessary to correct DCM scheme, set DCM for the longer path before the OLP board to minimize the dispersion difference between the
 main and protection paths. 
Root Cause
When OLP protection switches, starts dispersion search and OTU3_LOF alarm. Switching time can reach tens seconds.
Suggestions
It is better to not use OLP protecion togever with 40G boards.

END