Which line rate choose for the 10GE and STM64 traffic

Publication Date:  2012-07-25 Views:  40 Downloads:  0
Issue Description
When we use tributary and line boards, for some boards such as TDX necessary to choose client interface type such as 10GE LAN or STM-64.
Only after choose this interface type possible to create traffic from this tributary board to a line board.
Alarm Information

After traffic creation can appear BUS_ERR alarms for the XCS, line and tributary boards.
216130      BUS_ERR               CR          start       2010-01-16 17:29:47      None                     NSA     NEW_BOARD                          board=1-5;para[0]=0x3,para[1]
=0xe9;   

Handling Process
1. Line rate can work in the standard mode - default value. This mode has rate 10.7G  and used with tributary board interface STM-64.
2. Line rate can work in speed up mode. This mode has rate 11.1G  and used with tributary board interface 10GE.
Line rate possible to change in the line board configuration/WDM configuration/advanced 
Root Cause
Problem of this alarms can be wrong line rate for the line board. Just line board rate inconsistent with the tributary board's port type.
These BUS_ERR alarms will appear for the tributary board, for both XCS boards and for the line board
Suggestions
Choose the right line rate of the line board according with the tributary board interface.

END