FAQ-How to Obtain the IP Address of the OptiX OSN 6800 Through the Internal Network Port

Publication Date:  2012-07-25 Views:  38 Downloads:  0
Issue Description
Q:
How to obtain the IP address conveniently on site if the IP address of the device is changed.
Alarm Information
Null
Handling Process
A:
Usually, the default IP address of the device is in the network segment of 129.9.x.x, which can be searched by using the navigator. If the IP address is changed on site, and the network segment is forgotten, use the following method to query the current IP address through the internal network port:
1. Connect the network cable to the internal network port (ETH1 or ETH2) of the device and set the IP address of the computer in the network segment 192.168.0.
2. Choose Start > Run and enter cmd to display the DOS command window.
3. Enter telnet 192.168.0.251 to directly connect to the SCC board. If the current SCC board is in slot 17, change the corresponding IP address to 192.168.0.250.
4. After successful login through telnet, enter ifShow in the command window. The information about the IP address, subnet mask, and MAC address is displayed. Then, log in to the board according to the obtained IP address.
Root Cause
Usually, the default IP address of the device is in the network segment 129.9.x.x., which can be searched by using the navigator. If the IP address is changed on site, and the network segment is forgotten, the current IP address can be queried through the internal network port.
Suggestions