No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

MOD_TYPE_MISMATCH alarm on Card N2EGT2

Publication Date:  2012-07-25 Views:  37 Downloads:  0
Issue Description
When N2EGT2 card is used with electrical ethernet SFP, there is an alarm on NE called MOD_TYPE_MISMATCH but traffic is up.
Alarm Information
MOD_TYPE_MISMATCH
Handling Process
Solution: set the port to electrical interface.
:cfg-replace-port:Bid,Pid,porttype,portlevel;
            Bid: 1~8,11~16(40G)/17(80G);
            Pid: 1~16
            porttype: sdh-opport, sdh-eport
            portlevel: sdh:stm-1, stm-4,stm-16,stm-64
            eth:ge
            SAMPLE:
           sdh:cfg-replace-port:1,1,sdh-opport,stm-4;
           eth:cfg-replace-port:1,1,sdh-eport,ge;
Root Cause
N2EGT2 default is optic interface board, so the port of N2EGT2 default is optic interface.  In this case, the port use Electrical SFP module, so it is report alarm of
 MOD_TYPE_MISMATCH.
Solution: set the port to electrical interface.
:cfg-replace-port:Bid,Pid,porttype,portlevel;
            Bid: 1~8,11~16(40G)/17(80G);
            Pid: 1~16
            porttype: sdh-opport, sdh-eport
            portlevel: sdh:stm-1, stm-4,stm-16,stm-64
                       eth:ge
            SAMPLE:
           sdh:cfg-replace-port:1,1,sdh-opport,stm-4;
           eth:cfg-replace-port:1,1,sdh-eport,ge;
Suggestions
None

END