10GE LAN service doesn't work due to OTU2 rate of line OTU board is not consistent with the rate of client service

Publication Date:  2012-07-25 Views:  47 Downloads:  3
Issue Description
After configuration of 10GE LAN service (see the file "Service_map.vsd" or "Service_map.jpg" for details),  the service doesn't work and alarms appear on line and 
client OTU boards which the service pass-through.
Alarm Information
BUS_ERR, ODU2_PM_SF (see the files "NS3_bus_error.JPG" and "NS3_bus_error1.JPG" for details)
Handling Process
Switch line rate mode of corresponded ODU2/OTU2 container of line OTU board to "speedup" mode to support transmission of 11.1 Gbit/s LAN service. 
For this, on each NE of the link on line OTU board do following configuration:
1) Open NE Explorer;
2) Open menu "Configuration" -> "WDM Interface"
3) Set "Line rate" mode to "Speedup Mode" (see the file NS3_line_rate_mode.JPG for details).
4) Press "Apply" button;
5) Backup NE database to FDB (using T2000 or Navigator command :dbms-copy-all:drdb,fdb0, :dbms-copy-all:drdb,fdb1).
Alarms on both client and line OTU boards must dissapear
Root Cause
Rate of the OTU2 container of line OTU board is not consistent with the rate of client service.  Port mapping mode of the client OTU board is "Bit transparent
transmission (11.1G)". But standart OTU2 container can carry 10.7G service only. 
Suggestions
Check whether speed of client 10GE port corresponds with the speed of WDM line transport container.