CXLN card showing RLOF alarm on card despite receiving Optical power in proper range

Publication Date:  2012-07-25 Views:  93 Downloads:  0
Issue Description
CXLLN card at Banglore core location is showing RLOF and LASER_MOD_ERR alarm despite of receiving optical power from SXC OSB-16 card from OSN2000 equipment.
Alarm Information
R_LOF and LASER_MOD_ERR alarm displayed.
Handling Process
By running command :cfg-add-port:20,1, sdh-opport,stm-16 we make changes in port type of CXLLN STM16 optical port from STM1 to STM16.
Root Cause
The configuration is incorrect.
The optical module should be STM-16,but the configuration is STM-1.
Suggestions
None.