FAQ-What Are the Formats for the Charging Pulse and Signal in the H248 Signaling Sent by Company A

Publication Date:  2012-07-25 Views:  26 Downloads:  0
Issue Description
Q:
What are the formats for the charging pulse and signal in the H248 signaling sent by company A?
Alarm Information
Null
Handling Process
A:
The softswitch of company A uses the SG packet of the MODIFY message to issue the charging pulse and times. The detailed format is as follows: Signals{amet/mpb{bpc=1}}
mpb:Metering Pulse Burst,This signal causes a burst of metering pulses to be applied to the termination. //Charging pulse
bpc:Burst Pulse Count,This parameter specifies the number of metering pulses to be applied as a burst on the line. The type, duration and pulse repetition interval for the metering pulses comprising the burst are provisioned in the MG.   //Charging pulse times. Integer type. Default value: 1.
      
Root Cause
Null
Suggestions
Null
      