FAQ-Why the LPU boards on NE40E&80E show alarm LANE3_CTC_ERR of PCS STATUS

Publication Date:  2012-07-27 Views:  52 Downloads:  0
Issue Description
Why the LPU boards on NE40E&80E show alarm LANE3_CTC_ERR of PCS STATUS 
Alarm Information
Slot=xx; In PICyy of LPUxx, LANE3_CTC_ERR of PCS STATUS resumed from failure.
Slot=xx; PICyy of LPUxx checked interrupt, because LANE3_CTC_ERR of PCS STATUS is detected. (Reason="NP-3 10G MAC PCS LANE3 CTC FIFO Error!")
Handling Process
Remove and reinstall the CR52L1XX, the CR52EBGF, or the CR52EBGE.
Applying the following commands, it can help determine whether the FPIC is properly installed:
[Quidway -diagnose]efu hal <slotid> reg dis 28 06 00 (PIC 0)
[Quidway -diagnose]efu hal <slotid> reg dis 28 07 00 (PIC 1)
If the returned value is all 0s, shown as follows, the FPIC is properly installed.
UID=0x00000028 SUID=0x00000006 Address=0x00000000 value=0x0000 0000 0000 0000
If the returned value is not 0, the FPIC needs to be removed and installed once again.
Root Cause
There are some packet losses and link down intermittently.
Suggestions
Version after V6R1(include) donnot have this problem