After configuring two classifiers with the same precedence value on the NE40E, it causes MPU reset

Publication Date:  2012-07-27 Views:  39 Downloads:  0
Issue Description
After configuring two classifiers with the same precedence value on the NE40E, it causes MPU reset. 
It happens in the following router's version:
NE40E-X8 Version V600R001C00B206
VRP NE40E-X8 Software Version VRPV500R007C02SPC200-GR
IPOS (R) Software Version IPOSV100R003C02SPC200
Alarm Information
May  6 2010 10:34:12 SW03 %%01SRM/4/MPUSWITCHCAUSE(l)[14]:VRP Find Exception cause MPU10 reset.
May  6 2010 10:34:12 SW03 %%01SRM/4/BOARDRESET(l)[15]:MPU10 will be reset, the reason is VRP reset selfboard because of find exception.
May  6 2010 10:34:12 SW03 %%01SRM/4/BOARDRESET(l)[16]:CLK15 will be reset, the reason is CLK reset with MPU.
Handling Process
It can be avoided by configuring following operation:
When apply command “classifier xx behavior xx precedence xx”, not to configure it with parameter “precedence”, for example:
[HUAWEI-trafficpolicy-1]classifier 1 behavior  1
[HUAWEI-trafficpolicy-1]classifier 2 behavior  2
Or, not to configure same “precedence” for different policies, for example:
[HUAWEI-trafficpolicy-1]classifier 1 behavior 1 precedence  10
[HUAWEI-trafficpolicy-1]classifier 2 behavior 2 precedence  20
Suggestions:
As a final solution for this issue, you can install the patch V600R001C00SPC003 on the router.
Root Cause
When the NE40E is generating a message indicating that the same precedence value has been set for two classifiers, an internal processing error leads to an invalid address access, causing a data access exception. This causes the MPU to be reset.