How to check Optical power of LINE port in CRPC board by Navigator when we can not check by "Optical power management" in T2000

Publication Date:  2012-07-25 Views:  62 Downloads:  0
Issue Description
When we need to determine the optical power value of LINE port in CRPC board for commissioning is difficult by Power meter becasue the power is high and can
 damage the meter, also for OSN6800 (V100R004 C04SPC510) we can not check the power value by T2000 (In "optical power management" appears: "/"). So the 
only easy way is to do it by Navigator.
Alarm Information
NULL
Handling Process
To check the power value by Navigator we can use this command:
:woptp:$bid,1,83,1,13,33,1,0,1,0,90   "$bid is the RPC slot number in Hex value"
For example ths command return:
Return: ncmd  0: 1f 13 33 00 00 01 00 01 00 90 ff ff ff 2A
For this repond value the parameter that we need is: ffffff2A
and then:
0xffffffff - 0xffffff2a= D5, D5(Hex)=213(Dec),  so, input power= -0.1* 213= -21.3
Root Cause
When we need to determine the optical power value of LINE port in CRPC board for commissioning is difficult by Power meter becasue the power is high and can
 damage the meter, also for OSN6800 (V100R004 C04SPC510) we can not check the power value by T2000 (In "optical power management" appears: "/"). So the 
only easy way is to do it by Navigator. This power value is useful to determine the paramenters to configure the IPA function in a link with RAMAN amplifier.