THE PPS PROTECTION FAILS

Publication Date:  2012-07-25 Views:  35 Downloads:  0
Issue Description
being configured the PPS protection on 2 EMS4 (version 7.15) boards as no-revertive, the fiber of the port 1 of the working board  faild and it is commuted to the port 1 of protection, when recovers the fiber, it is commuted to the port  1 working from the T2000. after some minutes of carrying out this commutation the 
fiber of the port 1 of the working board  faild  again and the service presents affectation because it doesn't commute to the protection port. the version SSN3GSCC board is 5.21.18.50P01 and of the T2000V200R007C03SPC003
      
      
Alarm Information
NULL
Handling Process
      when forcing the commutation  from the T2000 in the PPS protection , the state of the protecion changes to "normal." to "forced switching(protection to working) " (check presentation), this state should be changed again to "normal" for a new commutation, this is made giving right click on the lash “Switching Status” and to select clear (check presentation). the state in the 
lash “Switching Status” changes to "normal" (check presentation) 
Root Cause
when carrying out the commutation from the T2000 the lash “Switching Status” it shows the port as "forced switching(protection to working) ", this state should changes to "normal" for a new commutation.
Suggestions
      it should be kept in mind that when the commutation is made from the T2000  on the PPS protection, this it was executed in all the ports and in case the suitable procedure is not made previously, any port that failed in the working 
board  ethernet would affect the service because it would not commute
      