U2000 (iMHT06) can not add new NE which has CX600-X16 type

Publication Date:  2012-07-25 Views:  75 Downloads:  0
Issue Description
U2000 version : 
On U2000 Client, when user adds new NE with CX600-X16 type. It show a message "The device has exited". But we can't find it when searched with NE name and NE IP Address on U2000 � Main Topology function. Another thing, if we add this NE with ICMP device and it's successful.
Alarm Information
"The device has exited"
Handling Process
the patch number is U2000V100R001B02HCP0306 can solve this problem.this patch will change CX600-X as router.
Root Cause
In add device processing, there are some rule: if the devices are switch, ensuring that the device's MAC address is unique, namely switch MAC address is unique in the network. If the devices are router, ensuring that the device's IP address is unique, the MAC address's unique does not have regulation strictly. 
Early days, U2000 used CX600 as switch, this device's type was defined as HUAWEI switch. But, these device series have router's capability and in the network they are used as router. the MAC address's unique does not have regulation strictly. This two information bring on verifying the unique fail, cannot add the device.
Suggestions
null