No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Can't query optical power for NS2, TDX board for OSN8800 because the optical module is configured to be unused

Publication Date:  2012-07-25 Views:  49 Downloads:  0
Issue Description
The engineer said that he can't  query optical power for NS2, TDX board for OSN8800.
 
Alarm Information
Null
Handling Process
After configuring used in the optical module, the problem have been solved.
Root Cause
The cause that he can't query the optical power may be: 
1.Optical module don't insert in the board. Please check the alarm in the board. 
:alm-get-curdata-ext:0,0,0 
2.Configure unused to the optical module by error. 
:cfg-get-portuse:20,1,1; 
The engineer  ensure the reason is to configure unused in the optical module by error.
Suggestions
Notice: You need configure the optical module used if you want to query the optical power.

END