No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Error Code 1090613252 when upload OSN2500 topology

Publication Date:  2012-07-25 Views:  43 Downloads:  0
Issue Description
Not able to upload the NE configuration after creating new NE and for the existing NE as well. At the moment  only face this problem with OSN 2500 only. 
Alarm Information
None
Handling Process
Handling Process;
1. this error caused by some software bug in current version V100R002C01.
2. new patch SPC003 will recover this problem.
3. This new patch SPC003 just released and waiting customer confirmation to install.
Root Cause
When creating the new NE, then that new NE cannot upload. Got error message with Reasons: The function is not supported, Error Code: 1090613252. Found only when creating OSN2500.
Suggestions
Have some bug in U2000V100R002C01 and SPC003 patch probably will recover most of the bug in U2000V100R002C01.

END