No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

FAQ-why there is only V5_VCAIS alarm after SNCP switching but no TU_AIS alarm

Publication Date:  2012-07-25 Views:  50 Downloads:  0
Issue Description
One day there was SNCP switching in customer network,  then there appeared many V5_VCAIS alarms in somePQ1 and PQM channels, but no TU_AIS alarm, 
customer want to know the reason.
Alarm Information
V5_VCAIS 
Handling Process
There are some conditions for V5_VCAIS  alarm
 1. There must be error code while SNCP, and the error code must be in V5 byte
2. The platform alarm queue has overflowed 
3.There is V5_VCAIS  alarm while SNCP switching and it is before TU_AIS
4.there is 2.5s filtrate for GSCC board alarm. 
This problem can be explain as following:
  While SNCP switching there was V5 error code, then the tributary  board detect the V5_VCAIS  and report it to main control board platform, because there was 
problem of platform alarm queue has overflowed , so the alarms overflowed after reporting V5_VCAIS, then TU_AIS can't be reported, at the meantime because the 
end time of V5_VCAIS has overflowed too, so the main frame can't receive the alarm end time for V5_VCAIS, so the TU_AIS detected by tributary  board was  by 2.5s 
filtrate function 
Root Cause
1.There is V5 error code while switching 
2.The TU_AIS has been filtrated
Suggestions
Null 

END