Metro 1000 shows NO_BD_SOFT alarm

Publication Date:  2012-07-25 Views:  59 Downloads:  0
Issue Description
After customer received new SCB and install in NE,  NO_BD_SOFT alarm was reported.
:alm-get-curdata:0,ALL
CUR-ALM                                                                          
 NUM         BID   EID                               SEVERITY    STATE       START-TIME           END-TIME             PARA1  PARA2  PARA3  PARA4  PARA5  
10060       11    NO_BD_SOFT                        CR          start       2010-12-19 16:19:07  None                 0x01   0x00   0x19   0x01   0xff   
10061       11    NO_BD_SOFT                        CR          start       2010-12-19 16:19:07  None                 0x01   0x00   0x29   0x01   0xff   
                                                                                                                 
:ver: 5.37.07.31 20100811 20:45:03(for detailed information, please see the attachment)
Alarm Information
NO_BD_SOFT 
Handling Process
1, Use Simulating Software Package  to Load SCB;
2, Soft reset SCB, the alarm will disappear and services will not be affected
Root Cause
Alarm Parameters 3 has the following meanings:
 0x19:  ofs1/sccpkg.ini 
 0x29:  ofs2/sccpkg.ini 
RND confirmed that it is TR5 version and software is loaded by FTP, sccpkg.ini is not loaded;
Suggestions
This is TR5 version , we suggest that customer upgrade to the GA version M1000V3R7C02SPC200 which will be released in 2011.