MSP protection can't be created in signal site because NE database is abnormal

Publication Date:  2012-07-25 Views:  36 Downloads:  0
Issue Description
One day, engineer feedback one NE lose MSP configuration because of some reasons. when he create the MSP in T2000 or use commands, it still report error and can't create the MSP protection.
#9-19: [E-B][][2010-12-14 10:11:51+01:00]>
:cfg-add-rmspg:1,2fbi
#9-19:[E-B ][][2010-12-14 10:12:09+01:00]>
:cfg-set-rmsbdmap:1,w1,9,1,4
failed! cmd:0x8525 error:0x971c NSERR_CFG_BAD_AU4ID                     
#9-19: [E-B ][][2010-12-14 10:12:19+01:00]>
:cfg-set-rmsbdmap:1,e1,10,1,4
failed! cmd:0x8525 error:0x971c NSERR_CFG_BAD_AU4ID                     
#9-19:[E-B ][][2010-12-14 10:12:24+01:00]>
:cfg-get-rmsbdmap:1
                        MSSPR-PU-MAP
PG-ID   PU-ID   BOARD-ID   PORT-ID   AU4-MAP 
1       west1   0          0         0
1       east1   0          0         0
Alarm Information
error: 0x971c NSERR_CFG_BAD_AU4ID  
Handling Process

R&D resume the database of the NE in lab, create the MSP, report error. 

1,Using T2000 to upload the NE and delete the NE database, 

2, Download configuration to NE, then can create MSP successfully. 

So the reason of this problem is NE database abnormal, need to delete the NE database and download configuration from T2000 again.

Root Cause
1, the MSP configuration  wrong;
2, the problem of GSCC
3, the problem of Cross connection board
4, the problem of line board
Suggestions
In some case, some abnormal problem may caused by NE database abnormal, delete the NE database and download from T2000 again, the NE database can be 
normal.

END