Publication Date:  2012-07-25 Views:  37 Downloads:  0
Issue Description
In one NE, the EMS4 card, customer wants to configure LPT to enable protection for the ethernet service. Port 1 configuring is OK, but in port2, there is no enable option.
Alarm Information
Null, only the option disabled
Handling Process

1. Check the hardware for EMS4 card, and check the port working state, nothing is abnormal.

2. Compare the difference betweet port 1 and port 2 as LPT can work normally in port1, found service type is different, EPL service is in the port1, but EPLAN is in the port2.

3. Change the service form EPLAN to EPL in the port2,  it is normal for LPT option, and can be set. 

Root Cause

LPT function is supported in EMS4 card as confirmed according to the documents, so we shold check whether the port have some issue or not. As the first port is OK and LPT can be enabled, so we compare this two ports configuration in order to find the difference. Fininally, we found that EPL service is configured in the Port 1 but EPLAN service configured in the port2. So we change the service type  form EPLAN to EPL,  then enable LPT option appears normally.

LPT function can be used for EPL service only confirmed by R&D

Suggestions
LPT function can be used for EPL service only confirmed by R&D