WRG_BD_TYPE report for a short time after NE lost power

Publication Date:  2012-07-25 Views:  55 Downloads:  0
Issue Description
One day, Customer report find the NE report WRG_BD_TYPE for several minutes. customer want to know why the NE report this alarm and how to solve this problem
153065      24    WRG_BD_TYPE                       MJ          end         2011-01-30 11:43:04  2011-01-30 11:43:04  0x08   0xff   0xff   0xff   0xff   
  153062      24    WRG_BD_TYPE                       MJ          end         2011-01-30 11:43:04  2011-01-30 11:43:04  0x0b   0xff   0xff   0xff   0xff   
  153067      24    WRG_BD_TYPE                       MJ          end         2011-01-30 11:43:04  2011-01-30 11:43:04  0x11   0xff   0xff   0xff   0xff   
  153068      24    WRG_BD_TYPE                       MJ          end         2011-01-30 11:43:04  2011-01-30 11:43:05  0x01   0xff   0xff   0xff   0xff   
  153063      24    WRG_BD_TYPE                       MJ          end         2011-01-30 11:43:04  2011-01-30 11:43:06  0x02   0xff   0xff   0xff   0xff   
  153064      24    WRG_BD_TYPE                       MJ          end         2011-01-30 11:43:04  2011-01-30 11:43:07  0x12   0xff   0xff   0xff   0xff   
  153066      24    WRG_BD_TYPE                       MJ          end         2011-01-30 11:43:04  2011-01-30 11:43:09  0x03   0xff   0xff   0xff   0xff   
  153070      24    WRG_BD_TYPE                       MJ          end         2011-01-30 11:43:09  2011-01-30 11:43:10  0x0b   0xff   0xff   0xff   0xff   
  153069      24    WRG_BD_TYPE                       MJ          end         2011-01-30 11:43:09  2011-01-30 11:43:14  0x08   0xff   0xff   0xff   0xff   
  153071      24    WRG_BD_TYPE                       MJ          end         2011-01-30 11:43:11  2011-01-30 11:43:36  0x11   0xff   0xff   0xff   0xff   
  153072      24    WRG_BD_TYPE                       MJ          end         2011-01-30 11:43:11  2011-01-30 11:43:36  0x01   0xff   0xff   0xff   0xff   
 
Alarm Information
WRG_BD_TYPE 
Handling Process
When multi-id board report WRG_BD_TYPE  when NE lost power is normal, just need to explain to customer.
No need to handle 
Root Cause
1,after check the errlog, find the GSCC and other board all reset at nearly the same time
slot 25 GSCC errlog:
   2011-1-30 4:39:26 24 0xF0000004 0x1 
slot 24 GSCC errlog:
   2011-1-30 4:39:26 24 0xF0000004 0x1 
2, Find the line board are all multi-id board
3, Because when NE lost power, line board begin to work earlier than GSCC board, so the multi-id board will try its original logic board first, after GSCC begin to work, multi-id board finally can get the logic board recorded in GSCC board, so report the WRG_BD_TYPE  is normal
Suggestions
 Null

END