FAQ - what are the scenarios that can be implemented between sensor box and CCUB board on MA5616

Publication Date:  2012-07-25 Views:  90 Downloads:  0
Issue Description
Q:
what are the scenarios  that can be implemented between sensor box  and CCUB board on MA5616?
version:V800R307C00
Power supply 4830
Alarm Information
Null
Handling Process
A:
The scenarios that can be supported are listed as below:
scenario 1 with 4830:
ESC on CCUB ======= RS485 - 4830 - com ===== sensor box but 4815 can support more type of sensor minitor,not only digital-id, but aslo analog-id.which means it is able to support more types of sensors.
scenario 2 without 4830:
ALARM on CCUB ===== sensor
in this case, you have to comply with the wiring-order for each type of sencor orange + white and orange = reserved "0"
green + white and green = door "1"
blue + white and blue = arrester "2"
brown + white and brown = wiring "3"
this is correct wiring-order for each type of sensor