S9300 Master and Slave SRU

Publication Date:  2012-07-27 Views:  56 Downloads:  0
Issue Description
the current version is S9300 V100R001C02B125, 2 9300 connected with NE40E, for the desgin check the attachment.
Alarm Information
Null
Handling Process
After the commissioning engineer report the problem we analyse that and we found he did this test after he checked through the command that the board is registered and then immediately he poll out the board . 
1- slot 7 master 8 is slave (registered and Received realtime and routine data).
2- poll out slot 7, slot 8 become master and the ping not interrupted.
3- once slot 8 become master and 7 is slave he poll out slot 8 and the traffic is interrupted.
 before step 3 he must did one more command to confirm that solt 7 is Slave and received all data the command is :-
display switchover state
Slave MPU: Receiving realtime and routine data.
and if slot 7 (slave and not receive the all data the switch over will not success) . and this is the cause for the traffic intrupted.
Root Cause
The two S9306 are used to migrated the two S8505 one by one, so after the replacement the S8505 the customer want to check the HA for main board, 
So for the SRU test we just add the Vlan 192 on the S9306 and connect one cable between this Switch and NE40E-1 and then we login through the console to the router and we make ping �c 1000 10.74.145.5 and the ping are success, now the Slot 7 is master and slot 8 is slave
<9306-01>dis dev
S9306's Device status:
Slot  Sub Type  Online    Power      Register       Alarm      Primary
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 
1     -   LPU   Present   PowerOn    Registered     Normal     NA    
2     -   LPU   Present   PowerOn    Registered     Normal     NA    
3     -   LPU   Present   PowerOn    Registered     Normal     NA    
7     -   SRU   Present   PowerOn    Registered     Normal     Master
8     -   SRU   Present   PowerOn    Unregistered   -                Slave 
PWR1  -   PWR   Present   PowerOn    Registered     Normal     NA    
PWR3  -   PWR   Present   PowerOn    Registered     Normal     NA    
CMU1  -   CMU   Present   PowerOn    Registered     Normal     Master
FAN1  -     FAN   Present   PowerOn    Registered     Normal     NA    
FAN2  -     FAN   Present   PowerOn    Registered     Normal     NA  
 and when we poll out slot 7 (master) the ping is continue without any interruption. and now Slot 8 is become the master and slot 7 is slave
<9306-01>dis dev
S9306's Device status:
Slot  Sub Type  Online    Power      Register       Alarm      Primary
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 
1     -   LPU   Present   PowerOn    Registered     Normal     NA    
2     -   LPU   Present   PowerOn    Registered     Normal     NA    
3     -   LPU   Present   PowerOn    Registered     Normal     NA    
7     -   SRU   Present   PowerOn    Registered     Normal     Slave 
8     -   SRU   Present   PowerOn    Registered     Normal     Master
PWR1  -   PWR   Present   PowerOn    Registered     Normal     NA    
PWR3  -   PWR   Present   PowerOn    Registered     Normal     NA    
CMU1  -   CMU   Present   PowerOn    Registered     Normal     Master
FAN1  -   FAN   Present   PowerOn    Registered     Normal     NA    
FAN2  -   FAN   Present   PowerOn    Registered     Normal     NA 
and when we poll out this SRU Slot 8 (master) the traffic interrupted for around 1 min and 17 second. 
Suggestions
Also to locate the fault you can run this debug command 
debugging ha { all | message | resendipc | state }

END