Hostcar Warning appears in log file sating that process failed and cannot be deleted

Publication Date:  2012-07-27 Views:  49 Downloads:  0
Issue Description
Information :
Customer has ME60 with version of :VRP (R) software, Version 5.50 (ME60 V100R006C05SPC600) & patch version is : Patch: V100R006C05SPC029 &     V100R006C05SPC600 .
Issue :
Customer see many alarms similar to this alarm on the ME60 . customer doubt  this alarm may affect the service as it appears on many slots and at the same time the alarm is not clear understood by customer .
Alarm Information
Alarm:
May  1 2011 10:45:34 WAC-ME60 %%01ADA/4/PROCESS_FAIL(l):-Slot=8; Process failed, the source of error is loacated in:Hostcar Warning Slot:8,Carid:2976,Discard_Bytes:390016,discard-threshold:1024
May  1 2011 10:45:34 WAC-ME60 %%01ADA/4/PROCESS_FAIL(l):-Slot=7; Process failed, the source of error is loacated in:Hostcar Warning Slot:7,Carid:6809,Discard_Bytes:1283392,discard-threshold:1024
May  1 2011 10:45:33 WAC-ME60 %%01ADA/4/PROCESS_FAIL(l):-Slot=7; Process failed, the source of error is loacated in:Hostcar Warning Slot:7,Carid:2976,Discard_Bytes:387520,discard-threshold:1024
May  1 2011 10:45:33 WAC-ME60 %%01ADA/4/PROCESS_FAIL(l):-Slot=6; Process failed, the source of error is loacated in:Hostcar Warning Slot:6,Carid:6809,Discard_Bytes:1273600,discard-threshold:1024
May  1 2011 10:45:33 WAC-ME60 %%01ADA/4/PROCESS_FAIL(l):-Slot=6; Process failed, the source of error is loacated in:Hostcar Warning Slot:6,Carid:2976,Discard_Bytes:386048,discard-threshold:1024
May  1 2011 10:45:32 WAC-ME60 %%01ADA/4/PROCESS_FAIL(l):-Slot=5; Process failed, the source of error is loacated in:Hostcar Warning Slot:5,Carid:6809,Discard_Bytes:1263936,discard-threshold:1024
Handling Process
As 8k is HOSTCAR quantity of each card , 128k is default bandwidth of each HOSTCAR , if the traffic to CPU in one HOSTCAR reaches 128k , then you can find this alarm. So, due to the subscribers are too much , 128k is not enough , so we suggest to change it as 192k to reduce the alarm. 
 
Also, neither we do suggest to increase this value to bigger one nor prevent this alarm from appear as it is useful to not get an attack on the CPU of the BRAS and in case of attack this alarm will help to find out.
Please refer to attached file of logs.
Root Cause
 
This alarm tells that the incoming packets from ME60E subscribers to the ME60 CPU is too much and cross the threshould .
Suggestions
Null

END