No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

FAQ-In MA5680T R62, how to upgrade EP1A by CLI

Publication Date:  2012-07-25 Views:  161 Downloads:  0
Issue Description
Q:
In an FTTC network, the OLT is connected to a UA5000 using the EP1A board for upstream transmission. In MA5680T R62, how to upgrade EP1A by CLI?
Alarm Information
Null
Handling Process
A:
On the MA5680T, use TFTP to enter the loading command. For details, see the following:
1. In the diagnose mode, load the upgrade file to EPBA. 
MA5680T(diagnose)%%ONT load info program H801EPBA.lma tftp 192.168.0.2
2. Select EP1A to be upgraded. 
MA5680T(diagnose)%%ONT load select 0/8 1 9
3. Run the loading command to load the upgrade file. 
MA5680T(diagnose)%%ONT load start 
Different from R105, R62 does not support the Load starts and Load complete alarms or a command for querying the loading state. 
4. Wait for upgrade and check whether the upgrade is successful. 
You can run the following command to query the upgrade progress. 
MA5680T(diagnose)%%display ONT-load select 0/8 1 9
5. Run the following command to stop the upgrade. 
MA5680T(diagnose)%%ONT load stop
6. Reset the board and then run the following command to query the version. 
MA5680T(config-if-epon-0/8)#display ont version 1 9
Root Cause
Null
Suggestions
Null

END