No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

FAQ - Why synchronization between 9 and 10 SCUL board can't complete successfully

Publication Date:  2012-07-25 Views:  61 Downloads:  0
Issue Description
Q:
Why synchronization between 9 and 10 SCUL board can't complete successfully?
ONT
SmartAX MA5600T V800R005C00SPC020
Alarm Information
18/05/2011 07:15:12 : 356-MA5680T-1 [ 172.17.74.82 ] Device Management: Duplicate files failed to backup board.
Handling Process
A:
Exist 3% probability that SCU boards can't synchronized/ As a result - unconsist data on Master and Standby SCUL boards and buffer occupied. Through OLT no any chance to load any file to ONT or MxU direction.
It possible only for some party of boards, which used Samsung chipset.
Root Cause
Null
Suggestions
If problem happens, need to check BAR code of board, 
Tool in attach have a base of such boards.
If board exist in a list - need to replace it.

END