FAQ-How to collect LSA database from RTN 950 microwave using hyper terminal

Publication Date:  2012-07-25 Views:  55 Downloads:  0
Issue Description
In country X, Customer using third party microwave equipment plus huawei RTN 950. NMS management is passing through HUWEI ECC in different OSPF areas.
LSA database for Huawei RTN 950 and other vendor's MW are required to check synchronization in OSPF protocol. 
Alarm Information
No alarm
Handling Process
Following are steps to obtain LSA database: 
1.You must go to the site and connect the RTN NE to your computer or laptop by the network cable.
2.If the NE IP is 10.251.177.58, please change the IP of your computer or laptop to 10.251.0.254, then you can login the NE by Navigator. 
     Run the command below. Then you can get the debug IP, maybe it is 129.9.1.1  
     :cm-set-linkway:debug     (Default value is NMS)
     :cfg-set-runstack:3             (Default value is 2) 
     :cfg-get-debugip 
     :dbms-copy-all:drdb,fdb    
3.Please change the IP of your computer or laptop to 129.9.1.2, Then you can open the super terminal (Hyper terminal) and login the NE by the debug IP 129.9.1.1  (Check attachments photos)
     Run the command CmdShowOspfLSA in super terminal (Hyper terminal) and you can get the LSA DB.
4. Change the IP of your laptop again to 10.251.0.254, then login by Navigator 
     Run the command below. Then you returned back the NE to its original settings
     :cm-set-linkway:nms 
     :cfg-set-runstack:2
     :cfg-get-debugip 
     :dbms-copy-all:drdb,fdb
Root Cause
To obtain LSA database from OSPF virtual port, We should use lan cable and telnet using hyper terminal to RTN 950
Suggestions
Can connect OSPF port in NE using LAN cable if same network class. Whatever the IP of RTN itself.

END